Quick Info :
Digital Precision : Utilize the digital I2S interface boasting high precision 24-bit data for unparalleled audio quality.
Optimal Signal-to-Noise Ratio : Benefit from a remarkable 61 dBA signal-to-noise ratio, ensuring clear and crisp sound reproduction.
Enhanced Sensitivity :With a high sensitivity of -26 dBFS, capture audio with precision and clarity.
Rs 1,290.00
Quick Info :
Wavelength Sensitivity : 850nm
Case Material : Black epoxy for enhanced IR filtering
Package Type : ,5mm
Operating Voltage : 2.7V – 5.5V
Current Consumption : ≤1.5mA (typical)
Reception Distance : 10m – 30m (depends on model)
Carrier Frequency : 30kHz – 56kHz
Rs 30.00
Quick Info :
Operating Voltage: 5V
Current Consumption: 30-60mA
Frequency: 38kHz
Wavelength: 940nm
Rs 220.00
Quick Info :
Chip type: VS1838B
Operating Voltage: 3.3V to 5V
Current Consumption: 1.5mA peak
Receiving angle: 90 °
Reception distance: 17m
Rs 220.00
Quick Info :
Adjustable sensitivity (via blue digital potentiometer adjustment)
Operating voltage 3.3V-5V
Output Type : Digital switching outputs (0 and 1) -D0
Using LM393 comparator chip, stable
Rs 130.00
Quick Info :
Dark Resistance : ≥ 1MΩ (at 10 Lux)
Diameter : 5mm
Material : Cadmium Sulfide
Light Resistance : 5kΩ to 20kΩ (at 100 Lux)
Spectral Peak : ~540 nm
Power Rating : 100mW
Rs 15.00
Quick Info :
Power Rating : 100mW
Operating Voltage : Compatible with 3.3V to 5V systems
Diameter : 8mm
Material : Cadmium Sulfide (CdS)
Dark Resistance : ≥ 1MΩ (at 10 Lux)
Light Resistance : 5kΩ to 20kΩ (at 100 Lux)
Rs 45.00
Quick Info :
Liquid pH Value Detection Sensor
Heating voltage: 5±0.2V
Working current: 5-10mA
Electrode Probe for Liquid pH Value Detection Sensor Module
PH range: 0-14 PH
Temperature range: 0-60℃
Rs 5,990.00Rs 7,100.00
Quick Info :
Operating Voltage : 4V to 30V DC
Output Voltage : 0 mV + (10 mV/°C × Temperature)
Temperature Range : -55°C to +150°C
Accuracy : ±0.5°C at 25°C
Linear Scale Factor : 10 mV/°C
Response Time : Typically less than 1 second
Rs 140.00
Quick info:
Normally Open
Voltage:
Switching (VDC-MAX.): 200
Breakdown (VDC-MIN): 250
Arc-Quench (VDC-MIN): 200
Current:
Switching (AMPERES-MAX.): 0.5
Carry (AMPERES-MAX.): 1.2
Rs 90.00
Quick Info :
Optical sensor: IR and red LED combined with a photodetector
Measures absorbance of pulsing blood
I2C interface plus INT pin
3.3V power supply complete pulse oximeter and heart rate sensor solution, simplifies design, integrated LEDs, photo sensor, and high-performance analog front
Rs 490.00
Quick Info :
LED Peak Wavelength: 660nm/880nm
LED Supply Voltage: 3.3~5V
Interface: I2C Interface
Operating Temperature Range: -40°C to +85°C
Rs 590.00
Quick Info :
Test Voltage range: DC3 – 25V (on 5V) or DC3 – 16.5V (on 3.3V)
Monitors Both Charge and Discharge
Complete High-Side Current Sensing
Current Sensing up to 3A
Rs 1,950.00
Quick info:
Supply voltage: 3 to 5.5V
Module current: 50mA
Module interface: Serial (SO, SCK, CS), 16-bit SPI compatible
Thermocouple temperature range: 0 to 450°C
Module sensor temperature range: 0 to 1024°C
Rs 790.00
Quick Info :
Connection type : Normally Open
Actuation Distance (mm) : 15 ~ 25
Connecting cable length (cm) : 30
Rs 290.00
Quick Info :
LCD Size: 35.7*16.8mm
Operation Temperature: -15°c to 70°c
Humidity measurement range: 10%~99%
Rs 590.00
Quick Info :
Model: GY-521
Chip: MPU-6050
Power supply: 3.3V
Communication mode: standard IIC communication protocol
Rs 790.00
Quick Info :
Operating Voltage: 2.5V to 5.0V
Power consumption: 150mA
Detect/Measure: NH3, Nox, CO2, Alcohol, Benzene, Smoke
Typical operating Voltage: 5V
Rs 490.00
Quick Info :
Operating Voltage is +5V
Can be used to Measure or detect LPG, Alcohol, Propane, Hydrogen, CO and even methane
Analog output voltage: 0V to 5V
Digital Output Voltage: 0V or 5V (TTL Logic)
Rs 490.00
Quick Info :
Power requirements: 5 VDC
Current Consumption: 150mA
DO output: TTL digital 0 and 1 ( 0.1 and 5V)
AO output: 0.1- 0.3 V (relative to pollution), the maximum concentration of a voltage of about 4V
Detecting Concentration: 0.05-10mg/L Alcohol
Rs 590.00
Quick Info :
Power requirements : VCC – 5V±0.1
DO output : TTL digital 0 and 1 (0.1 and 5V)
AO output : 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
Detection Gas : Natural gas/Methane
Detection Concentration : 200-10000ppm (Natural gas / Methane)
Rs 590.00
Quick Info :
Operating Voltage: 3.3V DC to 5V DC
Output Current : 15mA
PCB Size : 32 x 14mm
Rs 240.00
Quick Info :
Measure range : 0.00-14.00 pH
Resolution : 0.01 pH
Accuracy : +/- 0.01 pH
Rs 2,790.00
Quick Info :
Biometric Pulse Rate or Heart Rate detecting sensor
Plug and Play type sensor
Operating Voltage: +5V or +3.3V
Current Consumption: 4mA
Rs 690.00
Quick Info
Working voltage : 5V
Output format : Digital switching output (0 and 1), and analog voltage output AO
Potentiometer adjust the sensitivity
Uses a wide voltage LM393 comparator
Rs 230.00
Quick info:
Operating Voltage: 3.3V to 5V DC
Output format: Digital switching output ( 0 and 1 )
LEDs indicating output and power
Rs 250.00
Quick Info :
Operating voltage: 3.3V~5V.
Adjustable sensitivity (shown in blue digital potentiometer adjustment)
Dual output mode,analog output more accurate.
A fixed bolt hole for easy installation.
With power indicator (red) and digital switching output indicator (green).
Rs 230.00
Quick Info :
Operating voltage : 3.3 V
Operating current : 4~5 mA
Signal to noise ratio : 54 dB
Rs 200.00
Quick Info :
Working voltage of 3.3V to 5V
Output form: digital switch output (0 and 1)
Using infrared reflection sensors TCRT5000
Test reflection distance: 1mm to 25mm
Rs 180.00Rs 270.00
Quick Info :
Conductivity : 0 – 9990 us/cm
TDS : 0 – 5000ppm
Temperature :
Degrees Celsius : 0.1 – 80,
Fahrenheit : 32.0 – 176
Accuracy : 2%
Rs 2,590.00
Quick Info :
Vcc Range Typical 3.0 – 5.5V
Collector Light Current
20 lux 10uA (typical)
100 lux 50uA (typical)
Spectral Detection
Detection Range 440nm-800nm
Rs 590.00
Quick info:
Temperature Cutoff: 102-145
Rated Current: 2A
Rated Voltage: 250V~
Rs 30.00
Quick info :
Model: TTP223.
Dimensions: 15mm x 11mm.
Input Voltage: 2 Volt – 5.5 Volts DC.
Rs 60.00